Changes

Jump to navigation Jump to search

Tools/Laser Cutter

287 bytes added, 22:12, 24 February 2021
Startup and Operation Procedure
#** Depending on the last user, some layers may start turned off.Double click the "No" under the Process column to toggle them back on (and, if needed, the No under Visible).
#** Unless you are sure what you are doing, Positioning Mode in LightBurn should be set to Mechanical Origin, and you should use the "Put Graph to Origin" function in LightBurn to align the upper right of your file with the upper right of the work area (and the 0,0 of the laser cutter)
# Ensure that the water in the chiller fully covers the metal coil(the lid for the water level is underneath the power conditioner on the top of the chiller). If not, top it up from the jug of '''distilled''' water (usually found under the table)
# Rotate laser potentiometer to 0 (fully CCW)
[[File:Laser control potentiometer.jpg|thumb|Location of potentiometer]]
# CamFive voltage regulator on (flip up red switch on regulator, left corner of room)
# Check that white output power bar is on
#* Push in blue button if red light is not lit
[[File:Laser power strip button.jpg|thumb|Power Strip]]
# Laser main power on (flip up blue power switch on right side of main laser unit)
# Turn on water chiller (bottom red rocker switch right side of laser cutter)
[[File:Laser control switches.jpg|thumb|Laser control switches]]#* Press poer power button to lower right of screen on chiller to put into Run mode
#* Check that Set Point is 21º C and Temp Diff is 0.5º C
#* If Water Temp is greater than about 24º C, wait until chiller has brought it down some
6
edits

Navigation menu